> The traditional electrical installation must be determined before starting the construction of how and where to control your buildings electrical systems;
INSTABUS EIB can be changed at any time for all functions or be expanded, not normally associated with it will damage and dust, without laying a new pipeline. Has a wide selection of possibilities. Building electrical systems of all materials and equipment are interconnected through a bus line. Bus line and 230V power lines parallel to the laying. As long as the trigger input device (sensor or button) it can be a actuator (such as curtain generator) perform all necessary switching instruction;
Compatibility, open:
> Instabus seamless compatibility members of the Union, both together, you can also replace each other;
> EIB Association adopted a unified programming software ETS;
High integration, high reliability:
> Bus, each branch can be connected under the 64 components, 15 to form a regional branch. System has a maximum of 15 regions can be connected 14 400 components;
EIB bus technology to a number of independent control areas such as lighting, curtains, air conditioning, ventilation, security and other integrated in an intelligent overall system, and in this system, each component can be achieved independent or centralized control;
Products rich in species range;
> EIB system can achieve a variety of control;
> Lighting controls, including switches and dimmers;
> Curtains opening and closing or down, the blinds down and angle adjustment;
> Outlet, water heater and the control of various appliances;
> Air Conditioning (HVAC) system control;
> Home security system (Ministry of Public Security of the acceptance of residential security needs);
> Light sensor control;
> Timing control;
> Phone remote equipment monitoring;
EIB components from the functions can be divided into three categories:
> Sensor;
> Implementation of the device;
> System Accessories;
Replace the traditional multi-panel button switches the EIB switch, and the traditional shape and install all types of 86-type switch, but can be achieved in a panel lighting, air conditioning, curtains and other control functions, truly multi-system integration;
EIB and other field bus protocol, as used in the serial asynchronous transfer mode, in order to improve reliability and to achieve the maximum transmission rate, EIB application of the CSMA / CA (Carrier Sense to avoid conflict with Multiple Access). Through this bus access technology, making a number of bus devices to send signals at the same time the signal is lost when the phenomenon does not occur, and EIB have their own definition of priority in order to ensure signal transmission in accordance with a certain sequence has.
Superiority
Simplistic, intelligent;
Compatibility, open;
High integration, high reliability;
Products rich in species range;
Application of CSMA / CA (Carrier Sense to avoid conflict with Multiple Access) technology.
Applications
Public building projects for hotels, convention centers, stadiums, airports, schools and museums and other places