K型熱電偶是一種溫度感測器,K型熱電偶通常和顯示儀表,記錄儀表和電子調節器配套使用。K型熱電偶通常由感溫元件、安裝固定裝置和接線盒等主要部件組成。
基本介紹
- 中文名:熱電偶
- 外文名:thermocouple
介紹
測溫原理
特點
綜述
熱電偶類別 | 代號 | 分度號 | 測量範圍 | 基本誤差限 |
鎳鉻-康銅 | WRK | E | 0-800℃ | ±0.75%t |
鎳鉻-鎳矽 | WRN | K | 0-1300℃ | ±0.75%t |
時間常數
熱惰性級別 | 時間常數(秒) | 熱惰性級別 | 時間常數(秒) |
Ⅰ | 90-180 | Ⅲ | 10-30 |
Ⅱ | 30-90 | Ⅳ | <10 |
規定的長時間使用溫度(℃) | 試驗溫度(℃) | 絕緣電阻值(Ω) |
≥600 | 600 | 72000 |
≥ 800 | 800 | 25000 |
≥1000 | 1000 | 5000 |
分度表
溫度 | 0 | -10 | -20 | -30 | -40 | -50 | -60 | -70 | -80 | -90 | -95 | -100 |
-200 | -5.8914 | -6.0346 | -6.1584 | -6.2618 | -6.3438 | -6.4036 | -6.4411 | -6.4577 | ||||
-100 | -3.5536 | -3.8523 | -4.1382 | -4.4106 | -4.669 | -4.9127 | -5.1412 | -5.354 | -5.5503 | -5.7297 | -5.8128 | -5.8914 |
0 | 0 | -0.3919 | -0.7775 | -1.1561 | -1.5269 | -1.8894 | -2.2428 | -2.5866 | -2.9201 | -3.2427 | -3.3996 | -3.5536 |
溫度 | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 | 80 | 90 | 95 | 100 |
0 | 0 | 0.3969 | 0.7981 | 1.2033 | 1.6118 | 2.0231 | 2.4365 | 2.8512 | 3.2666 | 3.6819 | 3.8892 | 4.0962 |
100 | 4.0962 | 4.5091 | 4.9199 | 5.3284 | 5.7345 | 6.1383 | 6.5402 | 6.9406 | 7.34 | 7.7391 | 7.9387 | 8.1385 |
200 | 8.1385 | 8.5386 | 8.9399 | 9.3427 | 9.7472 | 10.1534 | 10.5613 | 10.9709 | 11.3821 | 11.7947 | 12.0015 | 12.2086 |
300 | 12.2086 | 12.6236 | 13.0396 | 13.4566 | 13.8745 | 14.2931 | 14.7126 | 15.1327 | 15.5536 | 15.975 | 16.186 | 16.3971 |
400 | 16.3971 | 16.8198 | 17.2431 | 17.6669 | 18.0911 | 18.5158 | 18.9409 | 19.3663 | 19.7921 | 20.2181 | 20.4312 | 20.6443 |
500 | 20.6443 | 21.0706 | 21.4971 | 21.9236 | 22.35 | 22.7764 | 23.2027 | 23.6288 | 24.0547 | 24.4802 | 24.6929 | 24.9055 |
600 | 24.9055 | 25.3303 | 25.7547 | 26.1786 | 26.602 | 27.0249 | 27.4471 | 27.8686 | 28.2895 | 28.7096 | 28.9194 | 29.129 |
700 | 29.129 | 29.5476 | 29.9653 | 30.3822 | 30.7983 | 31.2135 | 31.6277 | 32.041 | 32.4534 | 32.8649 | 33.0703 | 33.2754 |
800 | 33.2754 | 33.6849 | 34.0934 | 34.501 | 34.9075 | 35.3131 | 35.7177 | 36.1212 | 36.5238 | 36.9254 | 37.1258 | 37.3259 |
900 | 37.3259 | 37.7255 | 38.124 | 38.5215 | 38.918 | 39.3135 | 39.708 | 40.1015 | 40.4939 | 40.8853 | 41.0806 | 41.2756 |
1000 | 41.2756 | 41.6649 | 42.0531 | 42.4403 | 42.8263 | 43.2112 | 43.5951 | 43.9777 | 44.3593 | 44.7396 | 44.9293 | 45.1187 |
1100 | 45.1187 | 45.4966 | 45.8733 | 46.2487 | 46.6227 | 46.9955 | 47.3668 | 47.7368 | 48.1054 | 48.4726 | 48.6556 | 48.8382 |
1200 | 48.8382 | 49.2024 | 49.5651 | 49.9263 | 50.2858 | 50.6439 | 51.0003 | 51.3552 | 51.7085 | 52.0602 | 52.2354 | 52.4103 |
1300 | 52.4103 | 52.7588 | 53.1058 | 53.4512 | 53.7952 | 54.1377 | 54.4788 | 54.8186 |
產品資料
W | R | 規格 | 內容 | ||||
N | 鎳鉻-鎳矽 K | ||||||
K | 鎳鉻-銅鎳 (鎳鉻-康銅)E | ||||||
1 | 無固定式裝置式 | ||||||
2 | 固定螺紋式 | ||||||
- | 3 | 活動式法蘭 | |||||
4 | 固定法蘭式 | ||||||
5 | 活動法蘭角尺形式 | ||||||
6 | 固定螺紋錐形保護管式 | ||||||
2 | 防濺式 | ||||||
3 | 防水式 | ||||||
4 | 隔爆式 | ||||||
0 | 16mm金屬保護管 | ||||||
1 | 20mm金屬保護管 | ||||||
安裝固定形式 | 接線盒形式 | 2 | 16mm瓷保護管 | ||||
3 | 20mm瓷保護管 | ||||||
4 | 25mm瓷保護管 | ||||||
W | R | □ | - | □ | □ | □ |
回響時間測量
為了使熱電偶的熱回響時間具有可比性,國家標準規定:熱回響時間應在專用水流試驗裝置上進行。該裝置的水流速度應保持0.4±0.05m/s,初始溫度在5-45℃的範圍內,溫度階 躍值為40-50℃。在試驗過程中,水的溫度變化應不大於溫度階躍值的±1%。被試熱電偶的置入深度為150mm或設計的置入深度。
由於熱電偶在室溫附近熱電勢很小,熱回響時間不容易測出,因此國家標準規定可採用同規格的K型熱電偶的熱電極組件替換其自身的熱電極組件,然後進行試驗。
試驗時應記錄熱電偶的輸出變化至相當於溫度階躍變化50%的時間T0.5,必要時可記錄變化10%的熱回響時間T0.1和變化90%的熱回響時間T0.9。所記錄的熱回響時間,應是同一試驗 至少三次測試結果的平均值,每次測量結果對於平均值的偏離應在±10%以內。此外,形成溫度階躍變化所需的時間不應超過被測試熱電偶的T0.5的十分之一。記錄儀器或儀表的響 應時間不應超過被試熱電偶的T0.5的十分之一。